<?xml version="1.0" encoding="UTF-8"?><!-- generator="wordpress.com" -->
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	>

<channel>
	<title>secondary-coils &amp;laquo; WordPress.com Tag Feed</title>
	<link>http://en.wordpress.com/tag/secondary-coils/</link>
	<description>Feed of posts on WordPress.com tagged "secondary-coils"</description>
	<pubDate>Sun, 29 Nov 2009 16:37:19 +0000</pubDate>

	<generator>http://en.wordpress.com/tags/</generator>
	<language>en</language>

<item>
<title><![CDATA[Desain Elemen Sensor  Fluxgate Menggunakan Kumparan Sekunder Ganda Untuk Meningkatkan  Resolusi   Sensor]]></title>
<link>http://zulaz.wordpress.com/2008/06/25/desain-elemen-sensor-fluxgate-menggunakan-kumparan-sekunder-ganda-untuk-meningkatkan-resolusi-sensor/</link>
<pubDate>Wed, 25 Jun 2008 03:53:49 +0000</pubDate>
<dc:creator>zulaz</dc:creator>
<guid>http://zulaz.wordpress.com/2008/06/25/desain-elemen-sensor-fluxgate-menggunakan-kumparan-sekunder-ganda-untuk-meningkatkan-resolusi-sensor/</guid>
<description><![CDATA[Zul Azhar[3,2], Rahmondia N. Setiadi [2], Yulkifli[1,2], Mitra Djamal[2], Khairurrijal[2] [1] KK Fis]]></description>
<content:encoded><![CDATA[<div class='snap_preview'><p class="MsoNormal" style="margin-bottom:12pt;text-align:center;" align="center"><strong><em><span style="color:black;">Zul Azhar<sup>[3,2]</sup>,</span></em></strong><em><span style="color:black;"> Rahmondia N. Setiadi <strong><sup><span>[2]</span></sup></strong>, <span>Yulkifli<sup>[1,2]</sup></span>,<sub><span> <span> </span></span></sub><span>Mitra Djamal<sup>[2]</sup></span>, Khairurrijal<sup><span>[2]</span></sup></span></em></p>
<p class="MsoNormal" style="text-align:center;" align="center"><em><span style="font-size:11pt;color:black;"><span> </span>[1] KK Fisika Instrumentasi, FMIPA, Univ. Negeri Padang </span></em></p>
<p class="MsoNormal" style="text-align:center;" align="center"><em><span style="font-size:11pt;color:black;"><span> </span>[2]. KK FisikaTeoritik Energi Tinggi dan Instrumentasi, FMIPA, Institut Teknologi Bandung</span></em></p>
<p class="MsoNormal" style="text-align:center;" align="center"><em><span style="font-size:11pt;color:black;">[3]. MAN, Kota Binjai</span></em></p>
<p class="MsoNormal" style="margin-bottom:12pt;text-align:center;" align="center"><strong><em><span style="font-size:11pt;color:black;"><a href="mailto:azhar2206r@yahoo.com">azhar2206@yahoo.com</a></span></em></strong></p>
<p class="MsoNormal" style="text-align:center;" align="center"><strong><em>ABSTRACT</em></strong></p>
<p class="MsoNormal" style="text-align:justify;"><em>The article explains<span> </span>fluxgate magnetic sensor design by using double secondary coil. Fluxgate sensor element such as a primary coils, a secondary <span> </span>coils <span> </span>and sensor<span> </span>core. primer coils as internal<span> </span>magnetic field generator and secondary coils as receiver exchange of<span> </span>external field (sensing), so the resolution of<span> </span>fluxgate sensor depend on design of secondary coils<span> </span>element. Magnetic field in the secondary coil will be<span> </span>zero <span> </span>while no external magnetic field, moreover if external magnetic field exist so that exchange of magnetic field will take place in the secondary coil. Based on the analysis of the data was received by the sensor&#8217;s sensitivity<span> </span><span> </span>that was good that is </em><em><span lang="IN">405,75 mV/</span></em><strong><span style="font-family:Symbol;"><span>m</span></span></strong><em><span lang="IN">T. </span>The maximum absolute error that was received from the linear function approached above was 0,56 </em><strong><span style="font-family:Symbol;"><span>m</span></span></strong><em>T, happened in the magnetic field as big as -17.65 </em><strong><span style="font-family:Symbol;"><span>m</span></span></strong><em>T and the Level of the maximum relative error of the sensor system in this approach was 1,43% at -17.65 </em><span style="font-family:Symbol;"><span>m</span></span><em>T.</em></p>
<p class="MsoNormal"><em> </em></p>
<p class="MsoNormal"><strong><em>Key Words : Design, sensor element, <span> </span>fluxgate, secondary <span> </span>coils. Sensitivity</em></strong></p>
</div>]]></content:encoded>
</item>

</channel>
</rss>
